Setting the standard for Metal Halide!

Studies have shown the most productive method for indoor growing is by starting plants with Metal Halide and then switching to High Pressure Sodium grow lights. HORTILUX Metal Halide lamps are specially designed to provide the spectral energy required for beginning stages of plant growth. HORTILUX Metal Halide out performs most grow lamps because of high initial light intensity and consistent output of the exclusive EYE HORTILUX spectrum.
This exclusive EYE HORTILUX Spectrum gives HORTILUX Metal Halide lamps a distinct edge over our competition, providing 30% better spectral maintenance than our competitors. This prolongs lamp life, reduces lamp replacement costs and also results in reduced down-time and maintenance costs, making HORTILUX Metal Halide a great, cost effective solution to your plant growth needs – especially in the vegetative stages.
1000W Metal Halide Spectrum

Benefits
- Cost effective veg light for large grow areas.
- Produces faster growth vs other standard MH lamps.
- Ideal for vegetative growth.
Features
- Exclusive EYE HORTILUX Spectrum.
- Use with core & coil ballasts for optimal performance.
- High initial light intensity and consistent spectral output
- 30% better spectral maintenance than our competitors which prolongs lamp life reducing lamp replacement costs
- Full one-year warranty.
- Operated and tested before packaging.
- Made in Mentor, Ohio USA!
Select the lamp to view specifications
MSRP
$84.95
Product Number
53960
UPC
639125539609
Part Description
M1000B/BU/HTL
Wattage
1000W
Lamp Operating Position
Vertical ±15 degrees
Socket Type
Single-ended Mogul
Fixture Rating
Enclosed
Suggested Height Above Canopy1
4 ft.
Warm up Time
4 Minutes
Hot Restrike
15 Minutes
Can be Air Cooled
Yes
Ballast Requirement2
Magnetic Core & Coil: ANSI M47
Cooling Needed
3412 BTUs
Dimming
No
PPF (400-700nm)3
1400 μmol/sec
Warranty
1 Year
Country of Origin
USA
Initial Lumens
120,000
Kelvin
4200K
CRI
65
1Varies with room space, ventilation and reflector size, form and shape.
2Call us if you have any questions about lamp/ballast compatibility.
3UV and Far Red are not counted in PPF measurements.
MSRP
$86.95
Product Number
53967
UPC
639125539678
Part Description
M1000B/U/BT37/HTL
Wattage
1000W
Lamp Operating Position
Universal
Socket Type
Single-ended Mogul
Fixture Rating
Enclosed
Suggested Height Above Canopy1
4 ft.
Warm up Time
4 Minutes
Hot Restrike
15 Minutes
Can be Air Cooled
Yes
Ballast Requirement2
Magnetic Core & Coil: ANSI M47
Cooling Needed
3412 BTUs
Dimming
No
PPF (400-700nm)3
1400 μmol/sec
Warranty
1 Year
Country of Origin
USA
Initial Lumens
115,000
Kelvin
4200K
CRI
65
1Varies with room space, ventilation and reflector size, form and shape.
2Call us if you have any questions about lamp/ballast compatibility.
3UV and Far Red are not counted in PPF measurements.
MSRP
$74.95
Product Number
53941
UPC
639125539418
Part Description
M400/HOR/HTL
Wattage
400W
Lamp Operating Position
Horizontal ±15 degrees
Socket Type
Single-ended Mogul
Fixture Rating
Enclosed
Suggested Height Above Canopy1
3 ft.
Warm up Time
4 Minutes
Hot Restrike
15 Minutes
Can be Air Cooled
Yes
Ballast Requirement2
Magnetic Core & Coil: ANSI M59
Cooling Needed
1365 BTUs
Dimming
No
PPF (400-700nm)3
475 μmol/sec
Warranty
1 Year
Country of Origin
Japan
Initial Lumens
39,000
Kelvin
6500K
CRI
65
1Varies with room space, ventilation and reflector size, form and shape.
2Call us if you have any questions about lamp/ballast compatibility.
3UV and Far Red are not counted in PPF measurements.
DIRECTIONS
For best results:
- use the 400W only with ANSI rated M59 core & coil ballasts.
- use the 1000W BT37 and 1000W BT56 only with ANSI rated M47 core & coil ballasts.
All three lamps must be used in enclosed fixtures only.
M400/HOR/HTL operates in a horizontal ±15° burning position.
M1000B/U/BT37/HTL operates in a universal burning position.
M1000B/BU/HTL operates in a base up ±15° burning position.
WARNING
This lamp can cause serious skin burn and eye inflammation from short-wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.
RISK OF ELECTRIC SHOCK:
- Turn power off before inspection, installation or removal.
- Protect lamp from direct contact with liquids to avoid breakage from thermal shock.
RISK OF FIRE:
- Keep combustible materials away from lamp during operation. UNEXPECTED LAMP RUPTURE MAY CAUSE INJURY, FIRE, OR PROPERTY DAMAGE
- Do not exceed rated ballast voltage.
- Do not use lamp if outer glass is scratched or broken.
- Do not use beyond rated life.
- Do not turn on lamp until fully installed.
- Use only with a fixture and ballast rated for this product.
- Turn lamp off at least once a week for 15 minutes.
- Electrically insulate any metal to glass support in fixture.
CAUTION
RISK OF BURN:
- Allow lamp to cool before handling. LAMP MAY SHATTER AND CAUSE INJURY IF BROKEN
- Do not use excessive force when installing lamp.
- Dispose of lamp in an enclosed container.
- Wear safety glasses and gloves when installing lamp.
Conforms for: USA: 21CFR1040.30
Lamp contains mercury
How long to use lamps before replacing
Optimal Growth | 6-8 Months |
Average Growth | 9-10 Months |
Maintenance Growth | 10-12 Months |
Burn Hrs/Day | 24 |
Click here for disposal and recycle information on lamps containing mercury.
- 1000W BT56
-
MSRP
$84.95Product Number
53960UPC
639125539609Part Description
M1000B/BU/HTLWattage
1000WLamp Operating Position
Vertical ±15 degreesSocket Type
Single-ended MogulFixture Rating
EnclosedSuggested Height Above Canopy1
4 ft.Warm up Time
4 MinutesHot Restrike
15 MinutesCan be Air Cooled
YesBallast Requirement2
Magnetic Core & Coil: ANSI M47Cooling Needed
3412 BTUsDimming
NoPPF (400-700nm)3
1400 μmol/secWarranty
1 YearCountry of Origin
USAInitial Lumens
120,000Kelvin
4200KCRI
651Varies with room space, ventilation and reflector size, form and shape.
2Call us if you have any questions about lamp/ballast compatibility.
3UV and Far Red are not counted in PPF measurements. - 1000W BT37
-
MSRP
$86.95Product Number
53967UPC
639125539678Part Description
M1000B/U/BT37/HTLWattage
1000WLamp Operating Position
UniversalSocket Type
Single-ended MogulFixture Rating
EnclosedSuggested Height Above Canopy1
4 ft.Warm up Time
4 MinutesHot Restrike
15 MinutesCan be Air Cooled
YesBallast Requirement2
Magnetic Core & Coil: ANSI M47Cooling Needed
3412 BTUsDimming
NoPPF (400-700nm)3
1400 μmol/secWarranty
1 YearCountry of Origin
USAInitial Lumens
115,000Kelvin
4200KCRI
651Varies with room space, ventilation and reflector size, form and shape.
2Call us if you have any questions about lamp/ballast compatibility.
3UV and Far Red are not counted in PPF measurements. - 400W
-
MSRP
$74.95Product Number
53941UPC
639125539418Part Description
M400/HOR/HTLWattage
400WLamp Operating Position
Horizontal ±15 degreesSocket Type
Single-ended MogulFixture Rating
EnclosedSuggested Height Above Canopy1
3 ft.Warm up Time
4 MinutesHot Restrike
15 MinutesCan be Air Cooled
YesBallast Requirement2
Magnetic Core & Coil: ANSI M59Cooling Needed
1365 BTUsDimming
NoPPF (400-700nm)3
475 μmol/secWarranty
1 YearCountry of Origin
JapanInitial Lumens
39,000Kelvin
6500KCRI
651Varies with room space, ventilation and reflector size, form and shape.
2Call us if you have any questions about lamp/ballast compatibility.
3UV and Far Red are not counted in PPF measurements. - Directions
-
DIRECTIONS
For best results:
- use the 400W only with ANSI rated M59 core & coil ballasts.
- use the 1000W BT37 and 1000W BT56 only with ANSI rated M47 core & coil ballasts.
All three lamps must be used in enclosed fixtures only.
M400/HOR/HTL operates in a horizontal ±15° burning position.
M1000B/U/BT37/HTL operates in a universal burning position.
M1000B/BU/HTL operates in a base up ±15° burning position.WARNING
This lamp can cause serious skin burn and eye inflammation from short-wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.
RISK OF ELECTRIC SHOCK:
- Turn power off before inspection, installation or removal.
- Protect lamp from direct contact with liquids to avoid breakage from thermal shock.
RISK OF FIRE:
- Keep combustible materials away from lamp during operation. UNEXPECTED LAMP RUPTURE MAY CAUSE INJURY, FIRE, OR PROPERTY DAMAGE
- Do not exceed rated ballast voltage.
- Do not use lamp if outer glass is scratched or broken.
- Do not use beyond rated life.
- Do not turn on lamp until fully installed.
- Use only with a fixture and ballast rated for this product.
- Turn lamp off at least once a week for 15 minutes.
- Electrically insulate any metal to glass support in fixture.
CAUTION
RISK OF BURN:
- Allow lamp to cool before handling. LAMP MAY SHATTER AND CAUSE INJURY IF BROKEN
- Do not use excessive force when installing lamp.
- Dispose of lamp in an enclosed container.
- Wear safety glasses and gloves when installing lamp.
Conforms for: USA: 21CFR1040.30
Lamp contains mercury - Replacement Guide
-
How long to use lamps before replacing
Optimal Growth 6-8 Months Average Growth 9-10 Months Maintenance Growth 10-12 Months Burn Hrs/Day 24 Click here for disposal and recycle information on lamps containing mercury.
- Growth Chart